Eni-Florence Battery Joint Stock Company Add: Lot C12 - Khanh Phu Industrial Zone - Yen Khanh - Ninh Binh - Vietnam Tel: (+84)2293 762 678 Fax: (+84) 303 762 345 Email: contact@eni-florence.com
| Nominal Voltage (V) | 12 V |
| Nominal Capacity | 10 hour rate (0.4 A to 10,50 V) 4 Ah |
| Weight | Approx. 1.5 ± 3% Kg (3.31 ± 3% Lbs) |
| Cold Cranking Amperes (-17.8°C) | 40 A |
| Design life at 25°C | 3~5 year |
| Case Material | PP |
| Length (L) | 113 +- 2 (4.45 +- 0,08) |
| Width (W) | 70 +- 2 (2.75 +- 0,08) |
| Height (H) | 85 +- 2 (3.35 +- 0,08) |
| Overall Height (HT) | 85 +- 2 (3.35 +- 0,08) |
| Unit | mm (inch) |
| 1. Charging at constant voltage | |||
|---|---|---|---|
| Step | Chargin Voltage | Chargin current | Chargin time |
| 1 | 14,8 +- 0,1V | Max 1.0 A | 24h |
| 2. Charging at constant Current | |||
| Step | Chargin Voltage | Chargin current | Chargin time |
| 1 | - | 0.4 A | Until voltage Stabilisation is established when three consecutive voltage measurements taken at 30 mins interrvals, remain constant |
- Nominal Operating Temperature : 25℃ (77℉)
- Storage: 5℃ ~ 40℃ (41℉~104℉)
- Discharge : -30℃ ~ 60℃ (-22℉~140℉)
- Charge: -30℃ ~ 60℃ (-22℉~140℉)
- High current charging at high temperatures above 50 degrees Celsius may cause acid leakage in the air outlet.
- Can be stored up to 6 months at 25℃ (77℉);
- If the battery is below 12.4V , battery must be recharged as soon as possible to prevent lead sulfation;
- Fully recharging is required before usage, and charged sooner if stored at higher temperature than 25℃ (77℉)
Export: Tell (+84)2293 762 678 DaNang Office: Tell (+84)2293 762 678 HCM Office: Tell (+84)2839 453 447